Release notes

LuminLogic NextGen 11.0.0

Version 11.0.0 of LuminLogic® links documents, records and their supporting evidence on one platform. Each section below says which modules changed and whether the change is new, improved or retired.

Version
11.0.0
Product
LuminLogic NextGen™
Upgrading from
LuminLogic 10.x
Retired in this release
Incidents, Discussions

MethodSense has helped medical device companies with quality and regulatory work for more than 25 years, with more than 1,000 regulatory and quality successes behind it. LuminLogic NextGen 11.0.0 builds that experience into the software your team uses every day.

The largest change is how much is now connected. Documents, change requests, CAPAs, complaints, risks, suppliers, training, audits, projects and products can be linked to each other and to their supporting evidence throughout their lifecycle. The history behind a quality decision can be traced from inside the record.

Controlled documents and records can now be edited live in the platform. Configurable workflows route each step to the people responsible. LuminLogic IQ drafts and analyzes content using MethodSense methods, and your team keeps review and approval.

For 10.x customers, 11.0.0 builds on the quality system and data you already have.

New

LuminLogic IQ

Applies to: documents, CAPAs, complaints, collections, traceability matrices, dashboards, projects

LuminLogic IQ brings MethodSense’s quality and regulatory methods into your workspace. It works only with information you can already reach, within your existing permissions and controls.

IQ drafts and analyzes. Nothing it writes is saved to a record until someone on your team saves it.

Who decides. Your team stays in control of review, judgment and approval. IQ doesn’t sign, approve or make regulatory determinations, and only a person can complete a signature.

LuminLogic IQ panel open beside a sterilization cycle deviation CAPA, listing contributing factors and a suggested root cause marked for review
IQ proposing a root cause on a CAPA from the equipment log and complaint history connected to it. The suggestion is marked for review.

With LuminLogic IQ you can

  • Summarize a single procedure or your entire QMS, working from what the documents say
  • Run an FDA QMSR and ISO 13485 gap analysis across the content you select
  • Draft the root cause analysis on a CAPA or complaint using accepted methods such as 5 Whys and fishbone, along with the corrective and preventive actions, informed by the records connected to it
  • Rewrite a procedure in plain language for the people who follow it
  • Draft a device description from a collection of technical documents you’ve already assembled
  • Build a traceability matrix from an Excel file, with a review step before anything is written
  • Surface trends and discrepancies in the data behind your dashboards
  • Run team capacity reports, analyze project status and import project tasks
Improved

Audit trails, connections and signed record export

Applies to: all modules

Audit trails

Audit trails have been updated so that every addition, modification and deletion of information is captured.

Connections

Quality records can be linked throughout their lifecycle, which gives each one a continuous history. A complaint can be linked to the change it led to. Training traces to the revision people were trained on, and each change keeps the rationale recorded for that revision.

Signed record export

When you export a record for an inspection or a technical file review, the signed document and its signature evidence stay together in the PDF. It shows who approved the document and when, and the footer records the export history.

New

Interface languages and timezones

Applies to: the whole interface

LuminLogic now supports eight interface languages. Teams in different countries work in the same QMS, on the same records, with the same controls and permissions.

EnglishEnglish
FrançaisFrench
DeutschGerman
ItalianoItalian
EspañolSpanish
PortuguêsPortuguese
ΕλληνικάGreek
日本語Japanese

Each user picks a language and works in their local timezone, while the organization keeps one QMS as its single source of truth.

Controlled content stays exactly as authored. Only the interface changes language, so translation never touches an approved record.

Improved

More granular permissions

Applies to: roles, documents, workflows, file downloads

Version 11 builds on LuminLogic’s role-based permissions. A role can now control what a user is allowed to do with content, in addition to what they can open.

New permissions cover draft documents, publishing, workflow initiation and file downloads. Editing, reviewing, approving, publishing and downloading are separate rights, so system access can follow your procedures and the responsibilities they assign.

WorkspaceApply a role everywhere
Functional area or modulee.g. Post-market, Documents
Foldere.g. Complaint handling
ViewEditReviewApprovePublishDownload

A user can hold different access in different parts of the QMS on a single account. An approver in post-market can be view-only in design without a second login.

New

Document authoring and version history

Applies to: documents

Documents can now be written and revised inside LuminLogic without leaving the controlled eQMS. Word documents are edited live in the platform and still download as Word files. Spreadsheets and Markdown edit the same way, and PDFs and Excel files can be viewed in place.

Live editing comes with the controls a regulated environment needs. You can mark a minor edit so it’s distinguishable from a substantive revision, update metadata across many documents at once, and create documents in bulk from uploaded files.

Version history shows every revision. Compare versions, restore an earlier revision, or preview and download a historical one. Tasks, assignments and record relationships stay connected as a document moves through revision and approval.

A controlled procedure, SOP1010 Record Management, open in the rich-text editor
A controlled procedure open in the editor.
Compare Revisions view showing two versions of SOP1040 side by side with a changed title line highlighted
Comparing two revisions of a risk management SOP.
New

Real-time collaboration

Applies to: documents, CAPAs

Process owners, Quality, Regulatory and other contributors often need to work on the same document or record, and waiting for one person to finish holds up the next.

In 11.0.0, several users can work in the same document or record at once. Everyone sees the current content and changes appear as they’re made, so files no longer go back and forth.

The same live editing is available in CAPA records. A team can work through the investigation, root cause analysis and corrective actions together in one place.

Illustration of several collaborators editing a gamma irradiation sterilization procedure at the same time
Illustration: several contributors in one draft procedure.
New

Configurable workflows

Applies to: documents, signatures, CAPAs, design transfer, complaints

The Workflow Designer lets you build your process into the system without writing code. What you draw is enforced as people work, so a record can’t move to a state your process doesn’t allow.

These workflows are included:

  • DocumentsChange a controlled document under an authorizing change request
  • DocumentsCollect signatures on a controlled document in a set order
  • SignaturesRoute an ad hoc signature request that doesn’t fit a standard path
  • CAPARun a CAPA from initiation through effectiveness check and closure
  • DesignAcknowledge design transfer to manufacturing
  • DocumentsMove a document to archived on its archive date
  • ComplaintsNotification Required and Advisory Notice Required, each starting a process that routes the work to the people responsible
New

The Regulatory Graph

Applies to: all linked records, traceability matrices, matrix templates, collections

An auditor follows a chain. A requirement leads to a design output, then to its verification, then to the change request that touched it and the training that followed. Most teams rebuild that chain by hand in the weeks before an inspection.

In 11.0.0, each link in that chain is a controlled record. It stores the version you linked to, who made the link and when, and it’s written to the audit trail. Together those links make up the Regulatory Graph.

  1. RequirementPinned at Rev B
  2. Design outputLinked to Rev B
  3. VerificationRecords who linked it and when
  4. Change requestHolds linked versions until refreshed
  5. TrainingTied to the revision trained on

Each arrow is a record with its own history in the audit trail. The trace still holds after both ends move to later revisions.

Link any record to any other from inside its content, and choose the version. A design input pinned to Rev B stays on Rev B. Documents linked to a change request keep their version until you deliberately refresh them.

A visual graph view is also available. Select a requirement and its connected evidence is laid out around it.

Traceability matrices

Every cell link counts as a graph connection. New: cell-level links shown in place, cell locking, background color, and multi-row move and delete.

Matrix templates

Versioned system templates, workspace templates you share, and personal ones. Save any matrix as a template or start the next one from one.

Collections

Add several items at once, sort and search the tree, and export a whole collection with its files as a ZIP.

Improved

CAPAs, complaints and change requests

Applies to: CAPAs, complaints, change requests

These records do the same job they always have. They now pick up the permissions, version history, links, workflows and audit trails described above, and the forms changed too.

New

  • Start a change request directly from a document, collection or traceability matrix
  • Every “No” and “N/A” on a change request requires a written justification
  • Associated Product/Process on a CAPA is a searchable selector tied to your real products, so a product has one name everywhere
  • Complaints carry Medical Device Report Required and Recall Required, each with its own due date
  • A conditional sub-type for medical devices and combination products, plus a root cause analysis due date
  • Complainant company and contact details, held behind permissions
  • CAPAs gained Verification Actions, an effectiveness check and a risk assessment field
  • Default CAPA reviewers and signers set once for the workspace

Improved

  • Closing a change request, CAPA or complaint now sets its closed date
  • Tabs that hold mandatory fields are marked, so you can see what’s outstanding without opening each one
  • Change request disposition expanded from one field to three
  • Action items added at closure show up right away on the Action Items tab
  • Change request tabs reworked throughout, with a new Trigger list
  • Complaints keep an update history, and the core investigation types were refreshed
Create Change Request form with identification, impact, training and verification tabs down the left side
The reworked change request form.
New

Products and parts

Applies to: products, parts, CAPAs, complaints, change requests

Products and parts are now records of their own. Build a product, connect its parts, and reference it from a CAPA, complaint or change request.

You can report across all of them at once, filtered by UDI, lot, serial number or recall, with links through to each underlying record. When a field issue raises a recall question, one report shows the complaints and CAPAs for the affected lots side by side.

Improved

Projects, tasks and time tracking

Applies to: projects, tasks, time tracking

A Kanban board joins the table and Gantt views, and Gantt charts can be filtered by assignee. Tasks number themselves hierarchically and renumber when you reorder them. They carry a risk field and can be assigned or reassigned without being opened.

Progress is now split into task progress and time progress. A task can be 90% done and at 200% of its estimate, and you need to see both numbers. The time tracker stays visible wherever you are and survives a dropped session, and cumulative time exports keep their Excel formulas.

Project planning view with a numbered task hierarchy, estimated and actual hours, and progress bars
A design project’s task hierarchy with estimated hours, actual hours and progress.
Improved

Reporting

Applies to: reports, analytics dashboards

Every content type now has reports. Group them by product, employee or project. Analytics charts export to PNG, CSV and Excel, and there are dedicated reports for signatures and for who has access to what.

Quality analytics dashboard with several charts
Quality analytics.
New

Help and knowledge packages

Applies to: Help Center, templates and regulatory content

The Help Center is inside LuminLogic. If an article doesn’t answer your question, you can start a conversation with our team without leaving the record you’re working on.

MethodSense maintains the regulatory content and templates in the platform as knowledge packages. They can be updated in your workspace without waiting for a platform release. You can see which version you’re running and add a package to an existing workspace.

Retired

Retired in 11.0.0

These 10.x modules are not part of LuminLogic NextGen 11.0.0:

  • Incidents
  • Discussions

If your team used them in 10.x, talk to your MethodSense contact about how that content is handled in your migration.

Also in this release

  • Functional areas hold folder trees as deep as you need, and you can name what a folder’s children are called
  • Light and dark display modes
  • Import users and contacts from a spreadsheet and manage them in bulk
  • Duplicate any record with its links intact
  • Recover deleted items from a single restore view
  • A workspace compliance profile describing the regulatory context it operates in
Moving from LuminLogic 10.x

Your documents, records and history come with you.

Older file formats stay readable in NextGen, so nothing turns into a file you can’t open. Archived material moves across too, and your administrator can review anything that needs a new location.

We plan each migration with the customer. Talk to your MethodSense contact before you schedule yours.

Not on LuminLogic yet? We’ll walk you through 11.0.0 using the records your team works with every week.

Request a demoExplore the platform